BUILDING ORIENTATION EFFECTS ON HVAC ENERGY PERFORMANCE: EDUCATIONAL BUILDING ANALYSIS IN CHINA'S HOT-SUMMER-COLD-WINTER ZONE

Authors

  • Rong Li Department of Architecture, Faculty of Design and Architecture, Universiti Putra Malaysia, 43400 Serdang, Malaysia
  • Zalina Shari Department of Architecture, Faculty of Design and Architecture, Universiti Putra Malaysia, 43400 Serdang, Malaysia
  • Mohd Zainal Abidin Ab. Kadir Department of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 Serdang, Malaysia

Keywords:

Building Orientation, Energyplus, Building Performance Simulation (BPS), Energy Consumption, Energy Use Intensity (EUI)

Abstract

This study investigated the impact of building orientation on HVAC energy consumption in educational buildings within China's hot summer and cold winter (HSCW) climate zone. Through EnergyPlus simulations of a representative teaching building in Chongqing, this research analysed heating, cooling, and total HVAC energy consumption patterns across 24 different orientations. The results demonstrate that building orientation significantly influences energy performance, with the south-facing orientation (180°) achieving optimal energy efficiency at 58.55 kWh/m², while the west-facing orientation (270°) exhibits the highest consumption at 63.01 kWh/m², representing a 7.62% variation. The study reveals that maintaining the building orientation within ±15° of due south can effectively optimise year-round energy performance, particularly in regions with significant seasonal variations. Furthermore, the findings indicate distinct seasonal patterns, with south-facing orientations demonstrating superior winter performance through optimal solar gain while requiring careful solar control strategies during summer. This study provides quantitative evidence to support the development of specific orientation design guidelines for building energy standards, offering practical insights for architects and urban planners in creating energy-efficient educational facilities in HSCW climate zones.

Downloads

Download data is not yet available.

Downloads

Published

2025-06-30

How to Cite

Li, R., Shari, Z., & Ab. Kadir, M. Z. A. (2025). BUILDING ORIENTATION EFFECTS ON HVAC ENERGY PERFORMANCE: EDUCATIONAL BUILDING ANALYSIS IN CHINA’S HOT-SUMMER-COLD-WINTER ZONE . Journal of Surveying, Construction and Property, 16(1), 118–132. Retrieved from https://peradaban.um.edu.my/index.php/JSCP/article/view/57371

Issue

Section

Articles